RDS Eclipse is a CTI designed specifically for PET production of 18F, 11C, and radioactive labeled compounds of the cyclotron system, with high production efficiency and a high degree of automation and control, high operation rate, high security, low running costs, low production costs, etc., the detailed explanation as follows:
1. Energy is 11Mev
Curie-grade PET with the production of radioisotopes High purity of synthetic medicine
2.Anion acceleration
Improve the beam uniformity, high extraction efficiency, reduce complexity
3. Self-shielding
Completely symmetrical closed magnetic formation from the shielding to reduce magnetic field leakage outside the accelerator is conducive to site selection
Pairs of semi-Park-shaped shield walls, shield the vast majority of radiation
4. Advanced target designing system
2 targets are produce
2 targets could enlarge to 8/16.
Single-beam incision, just screw once is able to fast loading and unloading, reducing leakage
Can also produce long-lived and short-lived isotopes
Conducive to clinical and research applications
5. Design of single-ring magnet
Deduce 10 times power losses
Reduce production fees and transportation fees
Increase the reliability of the system
6. 4 D electrode design
So that particles in each ring for more acceleration opportunities for flight
Particles in accelerators stay a short time
Minimize the inner activities in
Stronger magnetic in the certain current, higher productivity
7. Ravine's patented design
Four fan-shaped magnetic poles of the magnetic field gradient form the steep peak: the gap ratio is 27:1
Make the current focus better
8. Vertical installation design components
Reduce the extraction time
Improve access to develop the speed, safety in maintenance, and easy to control.
9. Vertical installation of extraction system
99% of extraction rate
Easy and convenient to maintain
10. Ion source placed vertically
To maintain good vacuum
A dedicated vacuum pump, allowing hierarchical extraction
Fast to maintain, easy and safe.
11. Senior automation and control design
Graphical interface, easy to learn
Full range of automated chemical synthesis and transport, chemical synthesis parameters of accurate, efficient compose rate
12. Low production costs, low operation cost, low-cost computer room construction
Self-shielding, compact design, low weight, small footprint, simplifying room shielding requirements, the cost savings in space
The low energy cost for cyclotron, saving on-going cost.
Automatic target system may turn on once only, continuous produce medicine and saving running cost
Small area target design ( produce FDG only need 1.2g 18 Oxygen water), also saving the cost of ingredients
13. 95% of turning on rate secure
14. The produced FDG has the accreditation from America FDA.
15. It could upgrade to GDS-Eclipse RD