Explanation of the Eclipse Cyclotron system

RDS  Eclipse is a CTI designed specifically for PET production of 18F, 11C, and radioactive labeled compounds of the cyclotron system, with high production efficiency and a high degree of automation and control, high operation rate, high security, low running costs, low production costs, etc., the detailed explanation as follows:

1. Energy is 11Mev

Curie-grade PET with the production of radioisotopes High purity of synthetic medicine

2.Anion acceleration

Improve the beam uniformity, high extraction efficiency, reduce complexity

 

3. Self-shielding

Completely symmetrical closed magnetic formation from the shielding to reduce magnetic field leakage outside the accelerator is conducive to site selection

Pairs of semi-Park-shaped shield walls, shield the vast majority of radiation

 


4. Advanced target designing system

2 targets are produce

2 targets could enlarge to 8/16.

Single-beam incision, just screw once is able to fast loading and unloading, reducing leakage

Can also produce long-lived and short-lived isotopes

Conducive to clinical and research applications

 

5. Design of single-ring magnet

Deduce 10 times power losses

Reduce production fees and transportation fees

Increase the reliability of the system


6.
4 D electrode design

So that particles in each ring for more acceleration opportunities for flight

Particles in accelerators stay a short time

Minimize the inner activities in

Stronger magnetic in the certain current, higher productivity

         


7.
Ravine's patented design

Four fan-shaped magnetic poles of the magnetic field gradient form the steep peak: the gap ratio is 27:1

Make the current focus better

 

8. Vertical installation design components

Reduce the extraction time

Improve access to develop the speed, safety in maintenance, and easy to control.

 

9. Vertical installation of extraction system

99% of extraction rate

Easy and convenient to maintain

 

10. Ion source placed vertically

To maintain good vacuum

A dedicated vacuum pump, allowing hierarchical extraction

Fast to maintain, easy and safe.

 

11. Senior automation and control design

Graphical interface, easy to learn

Full range of automated chemical synthesis and transport, chemical synthesis parameters of accurate, efficient compose rate

 

12. Low production costs, low operation cost, low-cost computer room construction

Self-shielding, compact design, low weight, small footprint, simplifying room shielding requirements, the cost savings in space

The low energy cost for cyclotron, saving on-going cost.

Automatic target system may turn on once only, continuous produce medicine and saving running cost

Small area target design ( produce FDG only need 1.2g 18 Oxygen water), also saving the cost of ingredients

 


13. 95% of turning on rate secure

 

14. The produced FDG has the accreditation from America FDA.

 

15. It could upgrade to GDS-Eclipse RD